Cadmium is a highly toxic heavy metal, even at low concentrations. Moreover, it bio-accumulates with a long biological half-life producing a wide variety of acute and chronic effects like cancer in humans. Therefore, there is significant interest in providing a portable and user-friendly sensor for heavy metal detection. A highly sen-sitive and selective electrochemical sensor for Cd(II) determination was developed as an alternative. The Cd (II) receptors were integrated into the sensor using an ion-imprinted polymer film (IIPs film). Accordingly, 4-amino-phenylacetic acid (4-APA) was electropolymerised in the presence of Cd(II) ions as a template using cyclic voltammetry (CV) on screen-printed carbon electrodes (SPCEs). Imprinted cavities were obtained after the alkaline elution of ions. Sensor characterisation was performed using SEM, ATR-FTIR and electrochemical methods, such as cyclic voltammetry (CV) and electrochemical Impedance Spectroscopy (EIS), and compared to control experiments (not imprinted polymeric film, NIP film). Analytical performances of the IIP sensor revealed a sensitivity 5-order of magnitude higher than the NIP response in a concentration range from 10 to 1200 nM of Cd (II). This technology can potentially be applied for water quality control and monitoring of heavy metals.

Disposable electrochemical sensor based on ion imprinted polymeric receptor for Cd(II) ion monitoring in waters

Costa, Marco;Di Masi, Sabrina
;
Malitesta, Cosimino
2023-01-01

Abstract

Cadmium is a highly toxic heavy metal, even at low concentrations. Moreover, it bio-accumulates with a long biological half-life producing a wide variety of acute and chronic effects like cancer in humans. Therefore, there is significant interest in providing a portable and user-friendly sensor for heavy metal detection. A highly sen-sitive and selective electrochemical sensor for Cd(II) determination was developed as an alternative. The Cd (II) receptors were integrated into the sensor using an ion-imprinted polymer film (IIPs film). Accordingly, 4-amino-phenylacetic acid (4-APA) was electropolymerised in the presence of Cd(II) ions as a template using cyclic voltammetry (CV) on screen-printed carbon electrodes (SPCEs). Imprinted cavities were obtained after the alkaline elution of ions. Sensor characterisation was performed using SEM, ATR-FTIR and electrochemical methods, such as cyclic voltammetry (CV) and electrochemical Impedance Spectroscopy (EIS), and compared to control experiments (not imprinted polymeric film, NIP film). Analytical performances of the IIP sensor revealed a sensitivity 5-order of magnitude higher than the NIP response in a concentration range from 10 to 1200 nM of Cd (II). This technology can potentially be applied for water quality control and monitoring of heavy metals.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0925400523002745-mmc1 (1) av online.docx

accesso aperto

Descrizione: supplementary material
Tipologia: Versione editoriale
Licenza: Creative commons
Dimensione 1.44 MB
Formato Microsoft Word XML
1.44 MB Microsoft Word XML Visualizza/Apri
1-s2.0-S0925400523002745-main oa.pdf

accesso aperto

Descrizione: testo principale
Tipologia: Versione editoriale
Licenza: Creative commons
Dimensione 1.1 MB
Formato Adobe PDF
1.1 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/482764
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 6
social impact