Food pathogens frequently cause foodborne diseases. There is a need to rapidly identify the source of the bacteria in order to contain their spread and epidemics. A pre-enrichment culture or a direct culture on agar plate are standard microbiological methods. In this review, we present an update on alternative molecular methods to nucleic acid-based detection for species identification. Biosensor-based methods rely on the recognition of antigen targets or receptors by antibodies, aptamers or high-affinity ligands. The captured antigens may be then directly or indirectly detected through an antibody or high-affinity and high-specificity recognition molecule. Various different detection methods are discussed, from label-free sensors and immunosensors to fluorescence-based ones. Each method shows advantages and disadvantages in terms of equipment, sensitivity, simplicity and cost-effectiveness. Finally, lab-on-a-chip (LOC) devices are introduced briefly, with the potential to be fast, sensitive and useful for on-site bacteria detection in food processing laboratories to check potential contamination by sample monitoring combined with a rapid pre-enrichment step.
Biosensors for the Detection of Food Pathogens
Valeria Mezzolla;Elisabetta Primiceri;Giuseppe Maruccio
2014-01-01
Abstract
Food pathogens frequently cause foodborne diseases. There is a need to rapidly identify the source of the bacteria in order to contain their spread and epidemics. A pre-enrichment culture or a direct culture on agar plate are standard microbiological methods. In this review, we present an update on alternative molecular methods to nucleic acid-based detection for species identification. Biosensor-based methods rely on the recognition of antigen targets or receptors by antibodies, aptamers or high-affinity ligands. The captured antigens may be then directly or indirectly detected through an antibody or high-affinity and high-specificity recognition molecule. Various different detection methods are discussed, from label-free sensors and immunosensors to fluorescence-based ones. Each method shows advantages and disadvantages in terms of equipment, sensitivity, simplicity and cost-effectiveness. Finally, lab-on-a-chip (LOC) devices are introduced briefly, with the potential to be fast, sensitive and useful for on-site bacteria detection in food processing laboratories to check potential contamination by sample monitoring combined with a rapid pre-enrichment step.| File | Dimensione | Formato | |
|---|---|---|---|
|
2014_[R]_Foods_Poltronieri_Biosensors for the Detection of Food Pathogens.pdf
accesso aperto
Tipologia:
Versione editoriale
Licenza:
PUBBLICO - Creative Commons 3.0
Dimensione
220.96 kB
Formato
Adobe PDF
|
220.96 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


