Since hundreds of volatile organic compounds (VOCs) produced by cell metabolism and released into the blood are excreted through exhaled breath or body fluids, the volatile composition (volatilome) of human samples reflects a subject’s state of health and early signals any abnormal deviation from healthy to disease. The chemical volatilomic profile of biological matrices can be transduced in a digital fingerprint by low cost and easy-to-use electronic nose (e-nose) devices based on gas sensor arrays. The e-noses can be used to aid clinical diagnosis supporting conventional diagnostic methods that sometimes require expensive or invasive medical procedures and delays in diagnoses. In this paper, an e-nose devoted to the human volatilome fingerprinting is presented. The device, code-named SPYROX, adopts an array of 8 metal-oxide (MOX) gas sensors and it is able to analyze response signals from different matrices (multi-matrix samples), dealing with exhaled breath and headspace analysis of human biological samples. While other works in literature neglect the design of the interface circuit, here an optimal multi-ranged analog front-end (AFE) circuit is proposed. It aims to the optimization of the read-out sensitivity which, ultimately, leads to accurate training datasets and, consequently, to high classification scores. Finally, the efficacy of the device is proved by testing both chemical standards and mixtures. As a result, a classification accuracy of 100% is achieved with a linear discriminant model. The experimental results give a proof on the system’s efficacy to the fingerprint analysis of complex gas mixtures, which are typical of human volatilome.
A Multi-matrix E-nose with Optimal Multi-ranged AFE Circuit for Human Volatilome Fingerprinting
Radogna, Antonio Vincenzo
;Grassi, Giuseppe;D'Amico, Stefano;Forleo, Angiola;Capone, Simonetta
2023-01-01
Abstract
Since hundreds of volatile organic compounds (VOCs) produced by cell metabolism and released into the blood are excreted through exhaled breath or body fluids, the volatile composition (volatilome) of human samples reflects a subject’s state of health and early signals any abnormal deviation from healthy to disease. The chemical volatilomic profile of biological matrices can be transduced in a digital fingerprint by low cost and easy-to-use electronic nose (e-nose) devices based on gas sensor arrays. The e-noses can be used to aid clinical diagnosis supporting conventional diagnostic methods that sometimes require expensive or invasive medical procedures and delays in diagnoses. In this paper, an e-nose devoted to the human volatilome fingerprinting is presented. The device, code-named SPYROX, adopts an array of 8 metal-oxide (MOX) gas sensors and it is able to analyze response signals from different matrices (multi-matrix samples), dealing with exhaled breath and headspace analysis of human biological samples. While other works in literature neglect the design of the interface circuit, here an optimal multi-ranged analog front-end (AFE) circuit is proposed. It aims to the optimization of the read-out sensitivity which, ultimately, leads to accurate training datasets and, consequently, to high classification scores. Finally, the efficacy of the device is proved by testing both chemical standards and mixtures. As a result, a classification accuracy of 100% is achieved with a linear discriminant model. The experimental results give a proof on the system’s efficacy to the fingerprint analysis of complex gas mixtures, which are typical of human volatilome.File | Dimensione | Formato | |
---|---|---|---|
A_Multi-matrix_E-nose_with_Optimal_Multi-ranged_AFE_Circuit_for_Human_Volatilome_Fingerprinting.pdf
accesso aperto
Tipologia:
Post-print referato (Refereed author’s manuscript)
Licenza:
Creative commons
Dimensione
3.11 MB
Formato
Adobe PDF
|
3.11 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.