OBJECTIVES. To examine the accuracy of transcranial Doppler to detect cerebral vasospasm in a patient population with aneurysmal subarachnoid hemorrhage. DESIGN. Prospective blind comparison of transcranial Doppler with cerebral angiography. Diagnostic accuracy of transcranial Doppler was assessed using receiver operating characteristic (ROC) analysis and likelihood ratios. Sensitivity and specificity were calculated using directly measured middle cerebral artery diameter as reference standard. SETTING. Intensive Care Unit of a large university teaching hospital. PATIENTS AND PARTICIPANTS. Twenty-two patients with subarachnoid hemorrhage were included. Patients underwent angiography on admission and after 8 days to diagnose vasospasm and were defined as having clinical vasospasm, angiographic vasospasm, or no vasospasm. MEASUREMENTS AND RESULTS. Sensitivity and specificity were 1.00 and 0.75 for angiographic vasospasm and both equal to 1.00 for clinical vasospasm diagnosis. A transcranial Doppler mean velocity threshold value of 100 cm/s for angiographic vasospasm and 160 cm/s for clinical vasospasm detection were chosen by ROC analysis. CONCLUSIONS. A Transcranial Doppler mean velocity threshold of 160 cm/s, calculated by the ROC analysis, accurately detects clinical vasospasm. A daily transcranial Doppler examination performed by a trained operator should be routinely used to provide early identification of patients at high risk and to orient therapeutic decisions.

The accuracy of transcranial Doppler to detect vasospasm in patients with aneurysmal subarachnoid hemorrhage

MASCIA, LUCIANA;
2003-01-01

Abstract

OBJECTIVES. To examine the accuracy of transcranial Doppler to detect cerebral vasospasm in a patient population with aneurysmal subarachnoid hemorrhage. DESIGN. Prospective blind comparison of transcranial Doppler with cerebral angiography. Diagnostic accuracy of transcranial Doppler was assessed using receiver operating characteristic (ROC) analysis and likelihood ratios. Sensitivity and specificity were calculated using directly measured middle cerebral artery diameter as reference standard. SETTING. Intensive Care Unit of a large university teaching hospital. PATIENTS AND PARTICIPANTS. Twenty-two patients with subarachnoid hemorrhage were included. Patients underwent angiography on admission and after 8 days to diagnose vasospasm and were defined as having clinical vasospasm, angiographic vasospasm, or no vasospasm. MEASUREMENTS AND RESULTS. Sensitivity and specificity were 1.00 and 0.75 for angiographic vasospasm and both equal to 1.00 for clinical vasospasm diagnosis. A transcranial Doppler mean velocity threshold value of 100 cm/s for angiographic vasospasm and 160 cm/s for clinical vasospasm detection were chosen by ROC analysis. CONCLUSIONS. A Transcranial Doppler mean velocity threshold of 160 cm/s, calculated by the ROC analysis, accurately detects clinical vasospasm. A daily transcranial Doppler examination performed by a trained operator should be routinely used to provide early identification of patients at high risk and to orient therapeutic decisions.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/520261
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 66
  • ???jsp.display-item.citation.isi??? 60
social impact