Food and drinks can be contaminated with pollutants such as lead and strontium, which poses a serious danger to human health. For this reason, a number of effective sensors have been developed for the rapid and highly selective detection of such contaminants. TBA, a well-known aptamer developed to selectively target and thereby inhibit the protein of clinical interest α-thrombin, is receiving increasing attention for sensing applications, particularly for the sensing of different cations. Indeed, TBA, in the presence of these cations, folds into the stable G-quadruplex structure. Furthermore, different cations produce small but significant changes in this structure that result in changes in the electrical responses that TBA can produce. In this article, we give an overview of the expected data regarding the use of TBA in the detection of lead and strontium, calculating the expected electrical response using different measurement techniques. Finally, we conclude that TBA should be able to detect strontium with a sensitivity approximately double that achievable for lead.

TBA for Sensing Toxic Cations: A Critical Analysis of Structural and Electrical Properties

Eleonora Alfinito
2023-01-01

Abstract

Food and drinks can be contaminated with pollutants such as lead and strontium, which poses a serious danger to human health. For this reason, a number of effective sensors have been developed for the rapid and highly selective detection of such contaminants. TBA, a well-known aptamer developed to selectively target and thereby inhibit the protein of clinical interest α-thrombin, is receiving increasing attention for sensing applications, particularly for the sensing of different cations. Indeed, TBA, in the presence of these cations, folds into the stable G-quadruplex structure. Furthermore, different cations produce small but significant changes in this structure that result in changes in the electrical responses that TBA can produce. In this article, we give an overview of the expected data regarding the use of TBA in the detection of lead and strontium, calculating the expected electrical response using different measurement techniques. Finally, we conclude that TBA should be able to detect strontium with a sensitivity approximately double that achievable for lead.
File in questo prodotto:
File Dimensione Formato  
ijms-24-14492.pdf

accesso aperto

Tipologia: Versione editoriale
Licenza: Creative commons
Dimensione 2.46 MB
Formato Adobe PDF
2.46 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/504767
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact