Three-point bending tests on Short Beam Shear (SBS) specimens are performed to investigate the interlaminar shear properties of plain weave fabric CFRP composites. The tests are performed in a controlled environmental chamber at two different elevated temperatures. The interlaminar shear properties of the specimens remain largely unaffected by the testing temperature. However, the SEM micrographs show different damage progressions between the specimens tested at 100 degrees C and 120 degrees C. Fibre ruptures and longer delamination between the plies, as a result of a high temperature, are observed in the specimens tested at 120 degrees C, which are not observed in the specimens tested at 100 degrees C. In addition, the acoustic emission activities during the tests are investigated by using piezoelectric sensors. The information-theoretic parameter, the Lempel-Ziv (LZ) complexity, is calculated for the recorded acoustic signals. The LZ Complexities are used for identifying the occurrence of the first delamination failure in the specimens. Additionally, the two features of the acoustic signals, LZ complexity and Weighted Peak Frequency (W.P-Freq), are used for distinguishing the different damage sources in the CFRP specimens. The results are well-supported by the time-frequency analysis of the acoustic signals using a Continuous Wavelet Transform (CWT).

Investigation of Interlaminar Shear Properties of CFRP Composites at Elevated Temperatures Using the Lempel-Ziv Complexity of Acoustic Emission Signals

Renna, G.
2022-01-01

Abstract

Three-point bending tests on Short Beam Shear (SBS) specimens are performed to investigate the interlaminar shear properties of plain weave fabric CFRP composites. The tests are performed in a controlled environmental chamber at two different elevated temperatures. The interlaminar shear properties of the specimens remain largely unaffected by the testing temperature. However, the SEM micrographs show different damage progressions between the specimens tested at 100 degrees C and 120 degrees C. Fibre ruptures and longer delamination between the plies, as a result of a high temperature, are observed in the specimens tested at 120 degrees C, which are not observed in the specimens tested at 100 degrees C. In addition, the acoustic emission activities during the tests are investigated by using piezoelectric sensors. The information-theoretic parameter, the Lempel-Ziv (LZ) complexity, is calculated for the recorded acoustic signals. The LZ Complexities are used for identifying the occurrence of the first delamination failure in the specimens. Additionally, the two features of the acoustic signals, LZ complexity and Weighted Peak Frequency (W.P-Freq), are used for distinguishing the different damage sources in the CFRP specimens. The results are well-supported by the time-frequency analysis of the acoustic signals using a Continuous Wavelet Transform (CWT).
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/477768
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact