The combined use of Lecce-University AERONET-photometer measurements and PM2.5, PM10, NO2, CO, and SO2 concentrations from different sites of Apulia-Region Air-Quality Agency represents the peculiarity of this study, which evaluates the impact of COVID-19 lockdown (LD) measures on aerosol and gaseous pollutants. Monthly-averaged columnar and surface parameters of the 2020-year were compared with corresponding monthly parameters of the ref-year obtained by averaging 2017, 2018, and 2019 measurements in order to evaluate LD measure impacts by Average Percent Departure (APD%). Photometer measurements showed that LD measures were likely responsible for the decrease in Aerosol Optical Depth (AOD). The APD% estimated between the 2020-and ref-year AOD (at 440 nm) was characterized by negative values from June to August, reaching the smallest mean value (−46%) in June. Moreover, the columnar aerosol load appeared less affected by continental urban/industrial particles than previous years in the summer of 2020. The PM-concentration-APD% calculated at ten sites was characterized by monthly trends similar to those of AOD-APD%. PM-APD% values varied from site to site and smaller values (up to −57% in June) were on average detected at urban/suburban sites than at background sites (up to −37%). The impact of LD measures on gaseous pollutants was observed from the onset of LD.

Impacts of the covid-19 lockdown measures on the 2020 columnar and surface air pollution parameters over south-eastern Italy

Romano S.
;
Catanzaro V.;Paladini F.
2021-01-01

Abstract

The combined use of Lecce-University AERONET-photometer measurements and PM2.5, PM10, NO2, CO, and SO2 concentrations from different sites of Apulia-Region Air-Quality Agency represents the peculiarity of this study, which evaluates the impact of COVID-19 lockdown (LD) measures on aerosol and gaseous pollutants. Monthly-averaged columnar and surface parameters of the 2020-year were compared with corresponding monthly parameters of the ref-year obtained by averaging 2017, 2018, and 2019 measurements in order to evaluate LD measure impacts by Average Percent Departure (APD%). Photometer measurements showed that LD measures were likely responsible for the decrease in Aerosol Optical Depth (AOD). The APD% estimated between the 2020-and ref-year AOD (at 440 nm) was characterized by negative values from June to August, reaching the smallest mean value (−46%) in June. Moreover, the columnar aerosol load appeared less affected by continental urban/industrial particles than previous years in the summer of 2020. The PM-concentration-APD% calculated at ten sites was characterized by monthly trends similar to those of AOD-APD%. PM-APD% values varied from site to site and smaller values (up to −57% in June) were on average detected at urban/suburban sites than at background sites (up to −37%). The impact of LD measures on gaseous pollutants was observed from the onset of LD.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/464352
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact