Functional, flexible, and integrated lab-on-chips, based on elastic membranes, are capable of fine response to external stimuli, so to pave the way for many applications as multiplexed sensors for a wide range of chemical, physical and biomedical processes. Here, we report on the use of elastic thin membranes (TMs), integrated with a reaction chamber, to fabricate a membrane-based pressure sensor (MePS) for reaction monitoring. In particular, the TM becomes the key-element in the design of a highly sensitive MePS capable to monitor gaseous species production in dynamic and temporally fast processes with high resolution and reproducibility. Indeed, we demonstrate the use of a functional MePS integrating a 2 μm thick polydimethylsiloxane TM by monitoring the dioxygen evolution resulting from catalytic hydrogen peroxide dismutation. The operation of the membrane, explained using a diffusion-dominated model, is demonstrated on two similar catalytic systems with catalase-like activity, assembled into polyelectrolyte multilayers capsules. The MePS, tested in a range between 2 and 50 Pa, allows detecting a dioxygen variation of the μmol L-1 s-1 order. Due to their structural features, flexibility of integration, and biocompatibility, the MePSs are amenable of future development within advanced lab-on-chips.

Highly Sensitive Membrane-Based Pressure Sensors (MePS) for Real-Time Monitoring of Catalytic Reactions

Zizzari Alessandra;Del Mercato Loretta L.;Pellegrino Paolo;Perrone Elisabetta;Monteduro Anna Grazia;Rinaldi R.;Viola Ilenia
;
Arima V.
2018-01-01

Abstract

Functional, flexible, and integrated lab-on-chips, based on elastic membranes, are capable of fine response to external stimuli, so to pave the way for many applications as multiplexed sensors for a wide range of chemical, physical and biomedical processes. Here, we report on the use of elastic thin membranes (TMs), integrated with a reaction chamber, to fabricate a membrane-based pressure sensor (MePS) for reaction monitoring. In particular, the TM becomes the key-element in the design of a highly sensitive MePS capable to monitor gaseous species production in dynamic and temporally fast processes with high resolution and reproducibility. Indeed, we demonstrate the use of a functional MePS integrating a 2 μm thick polydimethylsiloxane TM by monitoring the dioxygen evolution resulting from catalytic hydrogen peroxide dismutation. The operation of the membrane, explained using a diffusion-dominated model, is demonstrated on two similar catalytic systems with catalase-like activity, assembled into polyelectrolyte multilayers capsules. The MePS, tested in a range between 2 and 50 Pa, allows detecting a dioxygen variation of the μmol L-1 s-1 order. Due to their structural features, flexibility of integration, and biocompatibility, the MePSs are amenable of future development within advanced lab-on-chips.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/440099
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 9
social impact