Buildings built in warm climates are affected by severe overheating problems in summer, which negatively affects people's comfort and health. For these reasons, many users are forced to install cooling systems, leading to an increase in costs, consumption and a meaning impact on the environment. This study gives a valid method to monitor the overheating problems in buildings located in Mediterranean climates, without the use of cooling systems, but just with an accurate design of the envelope. The main challenge is to demonstrate that the hourly monitoring of the internal operative temperature (TOP), in accordance with the UNI EN ISO 52016, is able of defining univocally the performances of the building, taking into consideration the characteristics of the envelope. The optimization of this parameter permits to reach high level of internal comfort in a building, ensuring the designer to identify the best choice of building materials that compose the envelope. The TOP trends, for a whole year, are tested on a single-residential building model located in a warm Mediterranean climate, considering different configurations of the external walls. The results put in evidence that the best solutions are characterized by the presence of the double layer of tuff, with a very massive layer in the internal side and resistive layer outside. At the end, this study demonstrates that once optimized the envelope, it is easier to reach good values of internal operative temperature with the only use of a mechanical ventilation system.

Walls comparative evaluation for the thermal performance improvement of low-rise residential buildings in warm Mediterranean climate

Congedo P. M.;Baglivo C.
;
2020-01-01

Abstract

Buildings built in warm climates are affected by severe overheating problems in summer, which negatively affects people's comfort and health. For these reasons, many users are forced to install cooling systems, leading to an increase in costs, consumption and a meaning impact on the environment. This study gives a valid method to monitor the overheating problems in buildings located in Mediterranean climates, without the use of cooling systems, but just with an accurate design of the envelope. The main challenge is to demonstrate that the hourly monitoring of the internal operative temperature (TOP), in accordance with the UNI EN ISO 52016, is able of defining univocally the performances of the building, taking into consideration the characteristics of the envelope. The optimization of this parameter permits to reach high level of internal comfort in a building, ensuring the designer to identify the best choice of building materials that compose the envelope. The TOP trends, for a whole year, are tested on a single-residential building model located in a warm Mediterranean climate, considering different configurations of the external walls. The results put in evidence that the best solutions are characterized by the presence of the double layer of tuff, with a very massive layer in the internal side and resistive layer outside. At the end, this study demonstrates that once optimized the envelope, it is easier to reach good values of internal operative temperature with the only use of a mechanical ventilation system.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/435035
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 34
social impact