The causes of delamination and porosities during press forming of pre-consolidated flat laminates (blanks) made of carbon fiber-reinforced poly(ether ketone ketone) (PEKK) were addressed in this study. In particular, the quality of the blank laminate was investigated before and after infrared heating. The consolidation quality was evaluated by thickness measurements, non-destructive inspection (NDI), and optical microscopy. The experimental results confirmed that deconsolidation phenomena can be related to residual stresses formed during blank forming in an autoclave, then released during infrared heating (IR) of the blank, determining most of the defects in IR heated blanks. These defects, generated at the pre-heating stage, were not fully removed in the consolidation stage of the press forming process. An annealing treatment, performed on autoclave-consolidated blanks above the glass transition temperature of the matrix, was proposed to reduce the formation of defects during IR heating. The stress relaxation phenomena during annealing were modelled using a simple viscoelastic model

Effects of blank quality on press-formed PEKK/Carbon composite parts

Francesca Lionetto
;
Alfonso Maffezzoli
2018-01-01

Abstract

The causes of delamination and porosities during press forming of pre-consolidated flat laminates (blanks) made of carbon fiber-reinforced poly(ether ketone ketone) (PEKK) were addressed in this study. In particular, the quality of the blank laminate was investigated before and after infrared heating. The consolidation quality was evaluated by thickness measurements, non-destructive inspection (NDI), and optical microscopy. The experimental results confirmed that deconsolidation phenomena can be related to residual stresses formed during blank forming in an autoclave, then released during infrared heating (IR) of the blank, determining most of the defects in IR heated blanks. These defects, generated at the pre-heating stage, were not fully removed in the consolidation stage of the press forming process. An annealing treatment, performed on autoclave-consolidated blanks above the glass transition temperature of the matrix, was proposed to reduce the formation of defects during IR heating. The stress relaxation phenomena during annealing were modelled using a simple viscoelastic model
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/425400
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 24
social impact