An experimental study on new high temperature parabolic trough collector (PTC), with transparent receiver tube, based on gas-phase nanofluid, has been carried out for the first time in this work. Two-axes solar tracking PTC, with 4 m2 reflecting surface has been realized. Besides, two coaxial quartz tubes, with vacuum in the inner space were used as receiver pipe, with air-dispersed CuO nano-powders as working fluid. The aim of this work was to investigate the technological issues related to the use of gas-based nanofluid coupled with transparent quartz receiver and to evaluate the performance of the first prototype, comparing numerical and experimental results. The experimental campaign highlighted a critical issue related to nanopowder deposition within the receiver pipe, due to humidity. Moreover, in a day of measurement, the fluid temperature higher than 145 °C has been maintained for about 10 h, reaching a maximum value of 180 °C, with a mean efficiency of about 65%.

Experimental investigation of transparent parabolic trough collector based on gas-phase nanofluid

POTENZA, MARCO
Primo
;
MILANESE, Marco
;
COLANGELO, Gianpiero;DE RISI, Arturo
2017-01-01

Abstract

An experimental study on new high temperature parabolic trough collector (PTC), with transparent receiver tube, based on gas-phase nanofluid, has been carried out for the first time in this work. Two-axes solar tracking PTC, with 4 m2 reflecting surface has been realized. Besides, two coaxial quartz tubes, with vacuum in the inner space were used as receiver pipe, with air-dispersed CuO nano-powders as working fluid. The aim of this work was to investigate the technological issues related to the use of gas-based nanofluid coupled with transparent quartz receiver and to evaluate the performance of the first prototype, comparing numerical and experimental results. The experimental campaign highlighted a critical issue related to nanopowder deposition within the receiver pipe, due to humidity. Moreover, in a day of measurement, the fluid temperature higher than 145 °C has been maintained for about 10 h, reaching a maximum value of 180 °C, with a mean efficiency of about 65%.
File in questo prodotto:
File Dimensione Formato  
Article_GC_not marked(1).pdf

accesso aperto

Tipologia: Post-print referato (Refereed author’s manuscript)
Licenza: Creative commons
Dimensione 1.35 MB
Formato Adobe PDF
1.35 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/415133
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 101
  • ???jsp.display-item.citation.isi??? 92
social impact