Emerging techniques that use fiber-reinforced polymer -FRP- composites for strengthening and conservation of historic masonry are becoming increasingly accepted. In the last decades steel plates or wood frames were used for external confinement in containing the lateral dilation of masonry columns subjected to axial loads. In the last years FRP epoxy bonded strips or jackets were also employed to increase strength and ductility with encouraging results in terms of mechanical behavior and cost effectiveness. The behavior of masonry columns confined with FRP and subjected to axial compression is studied in this paper. An extended experimental investigation is presented in order to show the mechanical behavior of circular masonry columns built with calcareous blocks that may be commonly found in Italy and all over Europe in historical buildings. Different stacking schemes were used to build the columns, aiming to simulate the most common situations in existing masonry structures. Carbon FRP sheets were applied as external reinforcement; different amounts and different schemes of confining reinforcement were studied. The experiments include a new reinforcement technique made by using injected FRP bars through the columns cross section. Such a solution can be considered in place of a more traditional confinement, when external reinforcement must be avoided, or in addition to external reinforcement when an improved confinement effect is required. The structural behavior of masonry columns damaged under different levels of load and strengthened by using FRP reinforcements, was also investigated. Experimental results revealed the effectiveness of the FRP confinement for masonry columns, also for columns that were strongly predamaged before strengthening. A computation of the ultimate load was conducted using the Italian National Research Council recommendations to show an application of the design approach recently proposed in Italy. An existing analytical model, previously developed by the writers, was applied for computation of expected experimental values.

Structural Upgrading of Masonry Columns by using Composite Reinforcements

AIELLO, Maria Antonietta;MICELLI, Francesco;
2007-01-01

Abstract

Emerging techniques that use fiber-reinforced polymer -FRP- composites for strengthening and conservation of historic masonry are becoming increasingly accepted. In the last decades steel plates or wood frames were used for external confinement in containing the lateral dilation of masonry columns subjected to axial loads. In the last years FRP epoxy bonded strips or jackets were also employed to increase strength and ductility with encouraging results in terms of mechanical behavior and cost effectiveness. The behavior of masonry columns confined with FRP and subjected to axial compression is studied in this paper. An extended experimental investigation is presented in order to show the mechanical behavior of circular masonry columns built with calcareous blocks that may be commonly found in Italy and all over Europe in historical buildings. Different stacking schemes were used to build the columns, aiming to simulate the most common situations in existing masonry structures. Carbon FRP sheets were applied as external reinforcement; different amounts and different schemes of confining reinforcement were studied. The experiments include a new reinforcement technique made by using injected FRP bars through the columns cross section. Such a solution can be considered in place of a more traditional confinement, when external reinforcement must be avoided, or in addition to external reinforcement when an improved confinement effect is required. The structural behavior of masonry columns damaged under different levels of load and strengthened by using FRP reinforcements, was also investigated. Experimental results revealed the effectiveness of the FRP confinement for masonry columns, also for columns that were strongly predamaged before strengthening. A computation of the ultimate load was conducted using the Italian National Research Council recommendations to show an application of the design approach recently proposed in Italy. An existing analytical model, previously developed by the writers, was applied for computation of expected experimental values.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/300172
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 54
social impact