This article presents the MEG II Cylindrical Drift CHamber (CDCH), a key detector for the phase 2 of MEG, which aims at reaching a sensitivity level of the order 6x10^-14 of for the charged Lepton Flavour Violating mu+-->e+ gamma decay (Calibbi and Signorelli, 2018; Cei and Nicolò, 2014). CDCH is designed to overcome the limitations of the MEG tracker (Baldini et al., 2013) and guarantee the proper operation at high rates with long-term detector stability. CDCH is a low-mass unique volume detector with high granularity: 9 layers of 192 drift cells, few mm wide, defined by wires in a stereo configuration for longitudinal hit localization. The total radiation length is 1.5x10^-3 X0, thus minimizing the Multiple Coulomb Scattering (MCS) contribution and allowing for a single-hit resolution of 110 micometers (Baldini et al., 2016) and a momentum resolution of 130 keV/c. CDCH integration into the MEG II experimental apparatus (Baldini et al., 2018) will start in this year.

The new drift chamber of the MEG II experiment

Chiarello, G.
Membro del Collaboration Group
;
Grancagnolo, F.
Membro del Collaboration Group
;
Panareo, M.
Membro del Collaboration Group
;
Tassielli, G. F.
Membro del Collaboration Group
;
2019-01-01

Abstract

This article presents the MEG II Cylindrical Drift CHamber (CDCH), a key detector for the phase 2 of MEG, which aims at reaching a sensitivity level of the order 6x10^-14 of for the charged Lepton Flavour Violating mu+-->e+ gamma decay (Calibbi and Signorelli, 2018; Cei and Nicolò, 2014). CDCH is designed to overcome the limitations of the MEG tracker (Baldini et al., 2013) and guarantee the proper operation at high rates with long-term detector stability. CDCH is a low-mass unique volume detector with high granularity: 9 layers of 192 drift cells, few mm wide, defined by wires in a stereo configuration for longitudinal hit localization. The total radiation length is 1.5x10^-3 X0, thus minimizing the Multiple Coulomb Scattering (MCS) contribution and allowing for a single-hit resolution of 110 micometers (Baldini et al., 2016) and a momentum resolution of 130 keV/c. CDCH integration into the MEG II experimental apparatus (Baldini et al., 2018) will start in this year.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/431456
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact