Water-leak detection is extremely important for the optimization and rationalization of water resources. However, the techniques that are currently used for individuating leaks are extremely time-consuming; also, they require highly-experienced personnel and often become unreliable when measurements are not performed in specific operating conditions of the pipe (e.g., high water pressure). On such bases, in this paper, a time domain reflectometry (TDR)-based system for the non-invasive detection of leaks in underground metal pipes is presented. This system was validated through specific experimental tests, performed on a length of pipe where leaks were intentionally created. Experimental results demonstrate not only that the proposed system can successfully individuate the position of the leak (still reducing the inspection time with respect to traditional methods), but most importantly, they demonstrate that the system fares well even when multiple leaks are present. In this paper, after a brief description of the theoretical principles behind the proposed system, the experimental validation of the system is thoroughly described and commented on.

Performance evaluation of a TDR-based system for detection of leaks in buried pipes

CATALDO, Andrea Maria;CANNAZZA, GIUSEPPE;DE BENEDETTO, EGIDIO;
2012-01-01

Abstract

Water-leak detection is extremely important for the optimization and rationalization of water resources. However, the techniques that are currently used for individuating leaks are extremely time-consuming; also, they require highly-experienced personnel and often become unreliable when measurements are not performed in specific operating conditions of the pipe (e.g., high water pressure). On such bases, in this paper, a time domain reflectometry (TDR)-based system for the non-invasive detection of leaks in underground metal pipes is presented. This system was validated through specific experimental tests, performed on a length of pipe where leaks were intentionally created. Experimental results demonstrate not only that the proposed system can successfully individuate the position of the leak (still reducing the inspection time with respect to traditional methods), but most importantly, they demonstrate that the system fares well even when multiple leaks are present. In this paper, after a brief description of the theoretical principles behind the proposed system, the experimental validation of the system is thoroughly described and commented on.
2012
9781457717710
9781457717734
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/367013
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 2
social impact