This article explores the use of a microwave reflectometry-based system for the automatic control and real-time monitoring of the flow and of the liquid level in intravenous medical infusions. In medical and hospital contexts other kind of devices, mainly based on the optical detection and counting of the infusion drops, are used. Nevertheless, the proposed system is aimed at circumventing some typical drawbacks deriving from the optical sensing, thus allowing an efficient alternative solution for automatically monitoring the instantaneous flow of intravenous medical solutions. To this purpose, the proposed system combines microwave time domain reflectometry (TDR) measurements with a non-invasive sensing element (i.e.: strip electrodes directly attached to the external surface of the infusion bottle). Experimental results confirm that, by using low-cost portable TDR devices, the solution flow process can be accurately controlled. Therefore the proposed method can be successfully adopted as a promising control tool for in-hospital patient management as well as for telemedicine programs.

Development of a Remote System for Real-Time Control of Intravenous Drip Infusions

CATALDO, Andrea Maria;CANNAZZA, GIUSEPPE;
2011-01-01

Abstract

This article explores the use of a microwave reflectometry-based system for the automatic control and real-time monitoring of the flow and of the liquid level in intravenous medical infusions. In medical and hospital contexts other kind of devices, mainly based on the optical detection and counting of the infusion drops, are used. Nevertheless, the proposed system is aimed at circumventing some typical drawbacks deriving from the optical sensing, thus allowing an efficient alternative solution for automatically monitoring the instantaneous flow of intravenous medical solutions. To this purpose, the proposed system combines microwave time domain reflectometry (TDR) measurements with a non-invasive sensing element (i.e.: strip electrodes directly attached to the external surface of the infusion bottle). Experimental results confirm that, by using low-cost portable TDR devices, the solution flow process can be accurately controlled. Therefore the proposed method can be successfully adopted as a promising control tool for in-hospital patient management as well as for telemedicine programs.
2011
9781424493364
9781424493388
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/360723
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? ND
social impact