This paper outlines the results of investigations into the effects of radiation damage in the mini-MALTA depleted monolithic pixel sensor prototype. Measurements were carried out at Diamond Light Source using a micro-focus X-ray beam, which scanned across the surface of the device in 2 μm steps. This allowed the in-pixel photon response to be measured directly with high statistics. Three pixel design variations were considered: one with the standard continuous n− layer layout and front-end, and extra deep p-well and n− gap designs with a modified front-end. Five chips were measured: one unirradiated, one neutron irradiated, and three proton irradiated. The standard design showed a decrease of 12% in pixel response after irradiation to 1e15 neq∕cm2. For the two new designs the pixel response did not decrease significantly after irradiation. A decrease of pixel response at high biasing voltages was observed. The charge sharing in the chip was quantified and found to be in agreement with expectations.

Measurement of the relative response of small-electrode CMOS sensors at Diamond Light Source

Schioppa E. J.;
2020-01-01

Abstract

This paper outlines the results of investigations into the effects of radiation damage in the mini-MALTA depleted monolithic pixel sensor prototype. Measurements were carried out at Diamond Light Source using a micro-focus X-ray beam, which scanned across the surface of the device in 2 μm steps. This allowed the in-pixel photon response to be measured directly with high statistics. Three pixel design variations were considered: one with the standard continuous n− layer layout and front-end, and extra deep p-well and n− gap designs with a modified front-end. Five chips were measured: one unirradiated, one neutron irradiated, and three proton irradiated. The standard design showed a decrease of 12% in pixel response after irradiation to 1e15 neq∕cm2. For the two new designs the pixel response did not decrease significantly after irradiation. A decrease of pixel response at high biasing voltages was observed. The charge sharing in the chip was quantified and found to be in agreement with expectations.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/437341
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact